Вопрос
Как в программе на VB определить имя и IP-адрес компьютера?
Ответ
Подготовте проект, добавив в него форму.
На форму поместите:
— Кнопку с именем cmdGetHost
— 2 текстовых поля с именами txtHostName и txtIpAddr
Добавте в форму:
Option Explicit
Private Const MAX_WSADescription = 256
Private Const MAX_WSASYSStatus = 128
Private Const ERROR_SUCCESS As Long = 0
Private Const WS_VERSION_REQD As Long = &H101
Private Const WS_VERSION_MAJOR As Long = WS_VERSION_REQD \ &H100 And &HFF&
Private Const WS_VERSION_MINOR As Long = WS_VERSION_REQD And &HFF&
Private Const MIN_SOCKETS_REQD As Long = 1
Private Const SOCKET_ERROR As Long = -1
Private Type HOSTENT
hName As Long
hAliases As Long
hAddrType As Integer
hLen As Integer
hAddrList As Long
End Type
Private Type WSADATA
wVersion As Integer
wHighVersion As Integer
szDescription(0 To MAX_WSADescription) As Byte
szSystemStatus(0 To MAX_WSASYSStatus) As Byte
wMaxSockets As Integer
wMaxUDPDG As Integer
dwVendorInfo As Long
End Type
Private Declare Function WSAGetLastError Lib "WSOCK32.DLL" () As Long
Private Declare Function WSAStartup Lib "WSOCK32.DLL" (ByVal wVersionRequired As Long, lpWSADATA As WSADATA) As Long
Private Declare Function WSACleanup Lib "WSOCK32.DLL" () As Long
Private Declare Function gethostname Lib "WSOCK32.DLL" (ByVal szHost As String, ByVal dwHostLen As Long) As Long
Private Declare Function gethostbyname Lib "WSOCK32.DLL" (ByVal szHost As String) As Long
Private Declare Sub CopyMemory Lib "kernel32" Alias "RtlMoveMemory" (hpvDest As Any, ByVal hpvSource As Long, ByVal cbCopy As Long)
Public Function GetIPAddress() As String
Dim sHostName As String * 256
Dim lpHost As Long
Dim HOST As HOSTENT
Dim dwIPAddr As Long
Dim tmpIPAddr() As Byte
Dim i As Integer
Dim sIPAddr As String
If Not SocketsInitialize() Then
GetIPAddress = ""
Exit Function
End If
If gethostname(sHostName, 256) = SOCKET_ERROR Then
GetIPAddress = ""
MsgBox "Windows Sockets error " & Str$(WSAGetLastError()) & " has occurred. Unable to successfully get Host Name."
SocketsCleanup
Exit Function
End If
sHostName = Trim$(sHostName)
lpHost = gethostbyname(sHostName)
If lpHost = 0 Then
GetIPAddress = ""
MsgBox "Windows Sockets are not responding. " & "Unable to successfully get Host Name."
SocketsCleanup
Exit Function
End If
CopyMemory HOST, lpHost, Len(HOST)
CopyMemory dwIPAddr, HOST.hAddrList, 4
ReDim tmpIPAddr(1 To HOST.hLen)
CopyMemory tmpIPAddr(1), dwIPAddr, HOST.hLen
For i = 1 To HOST.hLen
sIPAddr = sIPAddr & tmpIPAddr(i) & "."
Next
GetIPAddress = Mid$(sIPAddr, 1, Len(sIPAddr) — 1)
SocketsCleanup
End Function
Public Function GetIPHostName() As String
Dim sHostName As String * 256
If Not SocketsInitialize() Then
GetIPHostName = ""
Exit Function
End If
If gethostname(sHostName, 256) = SOCKET_ERROR Then
GetIPHostName = ""
MsgBox "Windows Sockets error " & Str$(WSAGetLastError()) & " has occurred. Unable to successfully get Host Name."
SocketsCleanup
Exit Function
End If
GetIPHostName = Left$(sHostName, InStr(sHostName, Chr(0)) — 1)
SocketsCleanup
End Function
Private Function HiByte(ByVal wParam As Integer)
HiByte = wParam \ &H1 And &HFF&
End Function
Private Function LoByte(ByVal wParam As Integer)
LoByte = wParam And &HFF&
End Function
Private Sub SocketsCleanup()
If WSACleanup() <> ERROR_SUCCESS Then
MsgBox "Socket error occurred in Cleanup."
End If
End Sub
Private Function SocketsInitialize() As Boolean
Dim WSAD As WSADATA
Dim sLoByte As String
Dim sHiByte As String
If WSAStartup(WS_VERSION_REQD, WSAD) <> ERROR_SUCCESS Then
MsgBox "The 32-bit Windows Socket is not responding."
SocketsInitialize = False
Exit Function
End If
If WSAD.wMaxSockets < MIN_SOCKETS_REQD Then
MsgBox "This application requires a minimum of " & CStr(MIN_SOCKETS_REQD) & " supported sockets."
SocketsInitialize = False
Exit Function
End If
If LoByte(WSAD.wVersion) < WS_VERSION_MAJOR Or (LoByte(WSAD.wVersion) = WS_VERSION_MAJOR And HiByte(WSAD.wVersion) < WS_VERSION_MINOR) Then
sHiByte = CStr(HiByte(WSAD.wVersion))
sLoByte = CStr(LoByte(WSAD.wVersion))
MsgBox "Sockets version " & sLoByte & "." & sHiByte & " is not supported by 32-bit Windows Sockets."
SocketsInitialize = False
Exit Function
End If
SocketsInitialize = True
End Function
' Использование
Private Sub cmdGetHost_Click()
txtHostName = GetIPHostName()
txtIpAddr = GetIPAddress()
End Sub
Мир программирования на Visual BASIC 5.0 и HTML
Можно это сделать и не вылезая за рамки стандартного VB.
Для этого надо поместить на форму Winsock-control и когда необходимо прочесть имя DNS или IP компа, то необходимо прочитать поля LocalHostName и LocalIP этого компа.
ЗЫ: Я понимаю, что это не самое лучшее применение Winsock-контрола, но на мой взгляд оно проще, нежели приведенный выше метод.
fde
Copyright 2000-2004 Сообщество Чайников
Контактная информация